HP XP7 Storage User Manual

Page 217

Advertising
background image

Message ID

Message Text

Explanation

Code, check the status of the path

where the error was detected.

KAPL20025-W I/O (aa...aa) to path (bb...bb)

failed. Plugin status=cc...cc

Details

An I/O error occurred.
aa...aa: SCSI command
bb...bb: Name of Path that had

I/O error
cc...cc: Plugin status

Action

Execute the DLMgetras utility for

collecting HDLM error information,

and then contact your HDLM

vendor or the maintenance

company if there is a maintenance

contract for HDLM. For details on

the DLMgetras utility, see

The

DLMgetras Utility for Collecting

HDLM Error Information on page

7-2

.

KAPL20026-W I/O (aa...aa) to path (bb...bb)

failed. Host status=cc...cc

Details

An I/O error occurred.
aa...aa: SCSI command
bb...bb: Name of Path that had

I/O error
cc...cc: Host status

Action

Execute the DLMgetras utility for

collecting HDLM error information,

and then contact your HDLM

vendor or the maintenance

company if there is a maintenance

contract for HDLM. For details on

the DLMgetras utility, see

The

DLMgetras Utility for Collecting

HDLM Error Information on page

7-2

.

KAPL20027-W I/O (aa...aa) to path (bb...bb)

failed. Device status=cc...cc

Details

An I/O error occurred.
aa...aa: SCSI command
bb...bb: Name of Path that had

I/O error
cc...cc: Device status

Action

Execute the DLMgetras utility for

collecting HDLM error information,

and then contact your HDLM

vendor or the maintenance

company if there is a maintenance

contract for HDLM. For details on

Messages

8-53

Hitachi Dynamic Link Manager (for VMware®) User Guide