B.15 – HP 3PAR Remote Copy Software User Manual

Page 151

Advertising
background image

B.15

controlport

InForm OS Version 2.3.1

Remote Copy User’s Guide

slot

Specifies the PCI bus slot in the specified node using a number from

0

to

6

.

port

Specifies the Fibre Channel adaptor port number of the PCI card in the specified PCI

bus slot using

1

to

4

.

<IP_address>

Specifies the IP address for a Remote Copy interface.

<gateway_address>

Specifies the gateway address for a Remote Copy interface.

<netmask>

Specifies the netmask for a Remote Copy interface.

<MTU_size>

Specifies the MTU size for a Remote Copy interface using an integer from 100 through

9000. If no integer is specified, the value defaults to 1500.

<speed> half|full

Use only with the rcip speed subcommand. Specifies the speed setting (10, 100, or 1000)

and duplex setting (half or full) for a Remote Copy interface. In addition to this specifier,

you must also specify an interface using <node:slot:port>. If no speed or duplex settings are

specified, or if you specify auto with the

rcip speed

subcommand, the system auto-

negotiates the speed and duplex.

<connmode>

Specifies whether the port is used for a disk, host, or RCFC connection. This specifier must

be used when issuing the

config

command.

RESTRICTIONS

See the InForm OS Command Line Interface Reference for a complete list of restrictions.

The

controlport rcip addr

command is only allowed for node/slot/port combinations

where there is an interface installed.