Statrcopy, B.74 – HP 3PAR Remote Copy Software User Manual
Page 210

B.74
statrcopy
Remote Copy User’s Guide
InForm OS Version 2.3.1
COMMAND
statrcopy
DESCRIPTION
The
statrcopy
command displays statistics for Remote Copy volume groups.
SYNTAX
statrcopy [options <arg>]
AUTHORITY
Super, Service, Edit, Browse
OPTIONS
-d <seconds>
Specifies the interval, in seconds, in which statistics are sampled using an integer from
1
to
2147483
. If no interval is specified, the option defaults to an interval of two seconds.
-iter <number>
Specifies that I/O statistics are displayed a specified number of times as indicated by the
num
argument using an integer from
1
to
2147483647
.
-u k|m|g
Displays statistics as kilobytes (
k
), megabytes (
m
), or gigabytes (
g
). If no unit is specified, the
default is kilobytes.
-hb
Specifies that the heartbeat round-trip time of the links should be displayed in addition to
the link throughput.
SPECIFIERS
None.
RESTRICTIONS
This command requires the 3PAR Remote Copy license. Contact your local service provider for
further information.