Show version – HP StorageWorks 1510i Modular Smart Array User Manual
Page 138

show version
Description
Displays firmware version and hardware revision information for the MSA
chassis, system modules, and attached hard drive storage enclosures.
Syntax
show version [-all]
Operands
-all
[Optional] In addition to the information displayed with the version
command, this also displays individual hard drive information, including
capacity, firmware version, and serial number.
Example
CLI> show version
MSA1510i Firmware Revision: 1.00b1 (SGA043600G)
MSA1510i Hardware Revision: 7 (AutoRev: 0x020000)
MSA1510i Processor Revision: 2
iSCSI Daughterboard Primary Firmware Revision: v1.0.159 (active)
iSCSI Daughterboard Backup Firmware Revision: b1.0.0121
iSCSI Driver Revision: 159SCSI I/O Module Bus 0 Revision: 2.02
SCSI I/O Module Bus 1 Revision: 2.02
SCSI I/O Module Bus 2 Revision: <<NOT INSTALLED>>
SCSI I/O Module Bus 3 Revision <<NOT INSTALLED>>
Fan Control Module A Revision: 2.36
Fan Control Module B Revision: 2.30
Box 1
PROLIANT 8LCE
Rev: 1.16 (E07PMLJ137)
Box 1 Fan Control Module A Rev: 2.32
Box 1 Fan Control Module B Rev: 2.32
Box 2
PROLIANT 4LEE Rev: JB4F ()
newpage pi
138
Command reference