[Optional] The stripe size to assign (in KB). Valid values are 8, 16, 32,

64, 128, or 256 Kilobytes.
• RAID 0 uses stripe sizes 8, 16, 32, 64, 128, and 256. Default: 128 KB.
• RAID 1 uses stripe sizes 8, 16, 32, 64, 128, and 256. Default: 128 KB.
• RAID 5 uses stripe sizes 8, 16, 32, and 64. Default: 16 KB.
• RAID ADG uses stripe sizes 8, 16, 32, and 64. Default: 16 KB.

size=<size>MB|GB

[Optional] How much of the available space on the indicated drives is

to be used for the LUN, where <size> represents the LUN size followed

by MB or GB (when GB is entered, all return displays are converted to

MB). If no size is specified, the maximum available space of the disks is

assigned to the unit.

max_boot= enable|disable

[Optional] The size of the boot partition. By default, max_boot is enabled.
• enable = 8 GB boot partition (default)
• disable = 4 GB boot partition

cache=enable|disable

[Optional] Determines whether to use the array controller cache for the

LUN. By default, cache is enabled.
• enable = Uses the array controller cache (default)
• disable = Does not use the array controller cache

Example 1
To create a single LUN from an individual drive or group of drives:

CLI> add unit 0 data=”disk101-disk107 disk110” raid_level=adg stripe_size=64

First volume to be configured on these drives.

Logical Unit size = 69460 MB

RAID overhead = 0 MB

Total space occupied by new unit = 69460 MB

Free space left on this volume = 0 MB

Unit 0 is created successfully.