HP StorageWorks 1510i Modular Smart Array User Manual

Page 69

Advertising
background image

show perf

start perf

stop perf

clear perf

show cacheinfo

show taskstats

set debug

show eventlog

Example help add unit command and response

CLI> help add unit

Usage: ’add unit <#> raid_level=R

data=diskrange

[spare=diskrange]

[stripe_size=S]

[size=X<GB|MB>]

[max_boot=<enable/disable>]

[cache=<enable/disable>]

#={0-31} / R={0,1,5,6(ADG)} / X={positive integer} / S={8,16,32,64,128,256}

diskrange examples: DISK101

DISK101-DISK105

"DISK101 DISK112-DISK202 DISK314"

DISKxyy: x={1,2,3} (box #) / yy={01-14} (bay #)

ex: DISK111 - disk in box 1, bay 11

max_boot is enabled by default. it can be disabled for OS’s that don’t

support the creation of bootdrives > 4GB

cache is enabled by default. enables/disables cache for the new unit.

add unit creates a new logical unit using the specified settings

newpage pi

1510i Modular Smart Array Command Line Interface user guide

69