HP StorageWorks 1510i Modular Smart Array User Manual
Page 69

show perf
start perf
stop perf
clear perf
show cacheinfo
show taskstats
set debug
show eventlog
Example help add unit command and response
CLI> help add unit
Usage: ’add unit <#> raid_level=R
data=diskrange
[spare=diskrange]
[stripe_size=S]
[size=X<GB|MB>]
[max_boot=<enable/disable>]
[cache=<enable/disable>]
#={0-31} / R={0,1,5,6(ADG)} / X={positive integer} / S={8,16,32,64,128,256}
diskrange examples: DISK101
DISK101-DISK105
"DISK101 DISK112-DISK202 DISK314"
DISKxyy: x={1,2,3} (box #) / yy={01-14} (bay #)
ex: DISK111 - disk in box 1, bay 11
max_boot is enabled by default. it can be disabled for OS’s that don’t
support the creation of bootdrives > 4GB
cache is enabled by default. enables/disables cache for the new unit.
add unit creates a new logical unit using the specified settings
newpage pi
1510i Modular Smart Array Command Line Interface user guide
69