7.

Establish a serial connection to the CLI using an emulator program such as HyperTerminal.

NOTE:

the following example describes the HyperTerminal emulator program.

a. Connect the RJ-45Z end of the custom CLI configuration cable to the port on the front of the

controller. One custom CLI cable is shipped with the MSA.

b. Connect the DB9 end of the CLI cable to the serial port on the host server.
c. Set up a terminal emulator from the host computer using the following settings:

Serial port:

any open COM port

Bits per second:

8

Data bits:

19200

Parity:

none

Stop bits:

1

Flow control:

none

d. After opening the session, press Enter several times to display the CLI command prompt.

8.

At the CLI prompt, enter the following command:

CLI> download firmware <offline|online|xml>

where: