Appendix B: HP SNMP events 101


Trap types

Rules file

Description

Netcool

severity

34(13603380)

missing. This might affect the drive
enclosure air flow and cause an over
temperature condition. The operational

power supply automatically shuts down
after a short time, thereby disabling the
drive enclosure. This condition remains

active until either the problem is
corrected, or the operational power
supply shuts down, whichever occurs first.

sCellEventTrap-0d-
35(13603381)

13603381

This event occurs when a drive enclosure
power supply component fails.

Critical(5)

sCellEventTrap-0d-
47(13603399)

13603399

This event occurs when a drive enclosure
fan module is not operating properly. This

might affect the drive enclosure air flow
and cause an over temperature condition.
A single fan operating at high speed can

provide sufficient air flow to cool an
enclosure. Operating an enclosure at

temperatures approaching an
overheating threshold can damage
elements and might reduce the mean time

before failure of a specific element.

Critical(5)

sCellEventTrap-0d-

4b(13603403)

13603403

This event occurs when a drive enclosure

fan module is improperly installed or
missing. This affects the drive enclosure
air flow and can cause an over

temperature condition.

Critical(5)

sCellEventTrap-0d-

5b(13603419)

13603419

This event occurs when a drive enclosure

temperature sensor out of range condition
is reported by one of the drive enclosure
link modules.

Minor(3)

sCellEventTrap-0d-

5f(13603423)

13603423

This event occurs when the temperature of

Enclosure Link Module temperature sensor
is at a critical level. The operational
power supplies automatically shuts down

the drive bays after a short period of
time, thereby disabling the drive
enclosure. This condition remains active

until either the problem is corrected, or
the operational power supplies shut
down, whichever occurs first. For the

temperature threshold values, see the HSV
element manager GUI.

Critical(5)

sCellEventTrap-0d-

8d(13603469)

13603469

This event occurs when a drive enclosure

transceiver error is detected.

Critical(5)

sCellEventTrap-0d-
dd(13603549)

13603549

This event occurs when a drive enclosure
I/O module error occurs.

Critical(5)

sCellEventTrap-0d-
de(13603550)

13603550

This event occurs when a drive enclosure
I/O module is not communicating with

the other I/O module.

Minor(3)

sCellEventTrap-0d-

13603568

This event occurs when the status changes Clear (0)