HP Insight Management for Tivoli User Manual

Page 104

Advertising
background image

Appendix B: HP SNMP events 104


Trap types

Rules file

Description

Netcool

severity

3a(13603642)

module is operating normally.

sCellEventTrap-0e-

3b(13603643)

13603643

This event occurs when the Management

module malfunctions.

Critical(5)

sCellEventTrap-0e-

3c(13603644)

13603644

This event occurs when the Battery

module operation is degraded.

Minor(3)

sCellEventTrap-0e-

3d(13603645)

13603645

This event occurs when the Fan module

configuration is incorrect.

Critical(5)

sCellEventTrap-0e-

3e(13603646)

13603646

This event occurs when the Fan module

operation is degraded.

Minor(3)

sCellEventTrap-0e-

3f(13603647)

13603647

This event occurs when the Fan module is

operating normally.

Clear (0)

sCellEventTrap-0e-

40(13603648)

13603648

This event occurs when the power supply

is operating normally.

Clear (0)

sCellEventTrap-0e-
41(13603649)

13603649

This event occurs when the temperature
within an HSV300 controller returns to a

safe operating level.

Minor(3)

sCellEventTrap-0e-

42(13603650)

13603650

This event occurs when the temperature

within an HSV300 controller is becoming
too cold.

Minor(3)

sCellEventTrap-0e-

43(13603651)

13603651

This event occurs when the temperature

within an HSV300 controller is too cold.

Critical(5)

sCellEventTrap-0e-
44(13603652)

13603652

This event occurs when the temperature
within an HSV300 controller is updated.

Clear (0)

sCellEventTrap-0e-
45(13603653)

13603653

This event occurs when the temperature
sensor within an HSV300 controller

malfunctions.

Minor(3)

sCellEventTrap-0e-

46(13603654)

13603654

This event occurs when the Management

module operation is degraded.

Minor(3)

sCellEventTrap-0e-

47(13603655)

13603655

This event occurs when the Management

module status changes.

Clear (0)

sCellEventTrap-0e-

48(13603656)

13603656

This event occurs when the Initial status of

network switch embedded in an HSV300
controller.

Clear (0)

sCellEventTrap-0e-
49(13603657)

13603657

This event occurs when the normal
operation of network switch embedded in

an HSV300 controller.

Clear (0)

sCellEventTrap-0e-

4a(13603658)

13603658

This event occurs when the malfunction of

network switch embedded in an HSV300
controller.

Critical(5)

sCellEventTrap-0e-
4b(13603659)

13603659

This event occurs when the degraded
operation of the network switch

embedded in an HSV300 controller.

Minor(3)

sCellEventTrap-0e-

4c(13603660)

13603660

This event occurs when the status change

of the network switch embedded in
HSV300 controller.

Clear (0)

sCellEventTrap-0e-
4d(13603661)

13603661

This event occurs when the status change
of I/O module embedded in an HSV300

Clear (0)

Advertising