HP Insight Management for Tivoli User Manual

Page 78

Advertising
background image

Appendix B: HP SNMP events 78


Trap types

Rules file

Description

Netcool

severity

respond.

sCellEventTrap-06-

02(13601538)

13601538

This event occurs when a physical disk

drive reports a check condition error.

Clear (0)

sCellEventTrap-06-

03(13601539)

13601539

This event occurs when an exchange sent

to a physical disk drive or another
HSV300 controller through the mirror port
or a Fibre Channel port times out.

Minor(3)

sCellEventTrap-06-

04(13601540)

13601540

This event occurs when work is

unexpectedly sent to this HSV300
controller by a physical disk drive or
another HSV300 controller.

Minor(3)

sCellEventTrap-06-
05(13601541)

13601541

This event occurs when work is sent to a
physical disk drive or another HSV300

controller through the mirror port but the
controller does not respond.

Minor(3)

sCellEventTrap-06-

07(13601543)

13601543

This event occurs when a Target

Discovery Service Descriptor exchange
sent to a physical disk drive times out.

Minor(3)

sCellEventTrap-06-

08(13601544)

13601544

This event occurs when an excessive

number of link errors are detected on an
HSV300 controller Fibre Channel port.
This informational event is triggered by

the occurrence of an excessive number of
Tachyon chip link status errors detected
within a particular link status error type.

Clear (0)

sCellEventTrap-06-
09(13601545)

13601545

This event occurs when a physical disk
drive reports failure prediction threshold

exceeded errors.

Clear (0)

sCellEventTrap-06-

0a(13601546)

13601546

This event occurs when a physical disk

drive reports numerous check condition
errors.

Clear (0)

sCellEventTrap-06-
0b(13601547)

13601547

This event occurs when a non-data
exchange sent to physical disk drive has

timed out.

Minor(3)

sCellEventTrap-06-

0c(13601548)

13601548

This event occurs when a loop switch is

detected on a Fibre Channel port.

Clear (0)

sCellEventTrap-06-

1a(13601562)

13601562

This event occurs when a physical disk

drive exceeds its soft error threshold.

Clear (0)

sCellEventTrap-06-

1c(13601564)

13601564

This event occurs when an outbound

frame targeted to a physical disk drive
times out.

Minor(3)

sCellEventTrap-06-
1d(13601565)

13601565

This event occurs when a Fibre Channel
exchange to a physical disk drive is

retried

Minor(3)

sCellEventTrap-06-

1e(13601566)

13601566

This event occurs when an HSV300

controller has detected only one port of a
Fibre Channel device.

Critical(5)

sCellEventTrap-06-

13601567

This event occurs when a previously
reported Fibre Channel device with only

Clear (0)

Advertising