Hp sim forwarded trap (hpov-nnm.mib), Water cooled rack monitor (cpqwcrm.mib) – HP Insight Management for Tivoli User Manual
Page 163

Appendix B: HP SNMP events 163
Trap types
Rules file
Description
Netcool
severity
bt2SwStgNewRoot(42)
42
This event occurs when the bridge
becomes the new root of the
STG.
Clear (0)
bt2SwCistNewRoot(43)
43
This event occurs when the bridge
becomes the new root of the
CIST.
Clear (0)
bt2SwStgTopologyChanged(44) 44
This event occurs when there is a
STG topology change.
Clear (0)
bt2SwCistTopologyChanged(45) 45
This event occurs when there is a
CIST topology change.
Clear (0)
bt2SwHotlinksMasterUp (46)
46
This event occurs when master
interface is active.
Clear (0)
bt2SwHotlinksMasterDn (47)
47
This event occurs when master
interface is not active.
Clear (0)
bt2SwHotlinksBackupUp (48)
48
This event occurs when backup
interface is active.
Clear (0)
bt2SwHotlinksBackupDn (49)
49
This event occurs when backup
interface is not active.
Clear (0)
bt2SwHotlinksNone (50)
50
This event occurs when there are
no active interfaces.
Clear (0)
HP SIM forwarded trap (HPOV-NNM.MIB)
Trap types
Rules file
Description
Netcool
severity
hpOVMessageTrap (58916872) 58916872
This event occurs when SNMP/HTTP
events and WBEM/WMI indications
are forwarded as SNMP trap from
HP SIM.
Minor (3)
Water Cooled Rack Monitor (CPQWCRM.MIB)
Trap types
Rules file
Description
Netcool
severity
alarmSensorInternal (1)
—
This event occurs when status of
Internal sensor connected to Basic
CMC changes.
—
InternalMsgStatus:notAvail
InternalMsgStatus.1 —
Major (4)
InternalMsgStatus:configChang
ed
InternalMsgStatus.2 —
Minor (3)
InternalMsgStatus:error
InternalMsgStatus.3 —
Major (4)
InternalMsgStatus:ok
InternalMsgStatus.4 —
Clear (0)
InternalMsgStatus:alarm
InternalMsgStatus.5 —
Minor (3)
InternalMsgStatus:Minor (3)
InternalMsgStatus.6 —
Minor (3)
InternalMsgStatus:tooLow
InternalMsgStatus.7 —
Major (4)