Appendix B: HP SNMP events 49


Trap types

Rules file

Description

Netcool

severity

CpqFcTapeCntlrStatus:offline

CpqFcTapeCntlrStatu
s.3

Major (4)

cpqFcaCntlrActive (16014)

16014

This event occurs when the
backup array controller in a

duplexed pair switches to the
active role.

Clear (0)

cpqFca2PhyDrvStatusChange
(16016)

This event occurs when the status
of a physical drive changes.

CpqFcaPhyDrvStatus:unconfigure
d

1cpqHeCorrMemLog
Status.2

Minor (3)

CpqFcaPhyDrvStatus:ok

1cpqHeCorrMemLog
Status.3

Clear (0)

CpqFcaPhyDrvStatus:threshExce

eded

1cpqHeCorrMemLog

Status.4

Major (4)

CpqFcaPhyDrvStatus:predictiveF

ailure

1cpqHeCorrMemLog

Status.5

Major (4)

CpqFcaPhyDrvStatus:failed

1cpqHeCorrMemLog

Status.6

Critical (5)

CpqFcaPhyDrvStatus:unsupporte

d

1cpqHeCorrMemLog

Status.7

Major (4)

cpqFca2AccelStatusChange

(16017)

This event occurs when the status

of an array accelerator cache
board changes.

CpqFcaAccelStatus:invalid

CpqFcaAccelStatus.2 —

Minor (3)

CpqFcaAccelStatus:enable

CpqFcaAccelStatus.3 —

Clear (0)

CpqFcaAccelStatus:tmpDisabled CpqFcaAccelStatus.4 —

Minor (3)

CpqFcaAccelStatus:permDisable

d

CpqFcaAccelStatus.5 —

Major (4)

cpqFca2AccelBadDataTrap

(16018)

16018

This event occurs when an array

accelerator cache board loses
battery power.

Major (4)

cpqFca2AccelBatteryFailed
(16019)

16019

This event occurs when a battery
associated with the array

accelerator cache board fails.

Major (4)

cpqFca2CntlrStatusChange

(16020)

This event occurs when the status

of an external array controller
changes.

CpqFcaCntlrStatus:ok

CpqFcaCntlrStatus.2 —

Clear (0)

CpqFcaCntlrStatus:failed

CpqFcaCntlrStatus.3 —

Critical (5)

CpqFcaCntlrStatus:offline

CpqFcaCntlrStatus.4 —

Major (4)

CpqFcaCntlrStatus:redundantPat
hOffline

CpqFcaCntlrStatus.5 —

Minor (3)

CpqFcaCntlrStatus:notConnected CpqFcaCntlrStatus.6 —

Minor (3)