Appendix b: hp snmp events, Hp snmp events, Cr3500 raid controller (cpqcr.mib) – HP Insight Management for Tivoli User Manual

Page 20

Advertising
background image

Appendix B: HP SNMP events 20


Appendix B: HP SNMP events

HP SNMP events

The following tables list all of the HP ProLiant SNMP definitions delivered with the rules file for
Netcool/OMNIbus v5.0. The events are organized according to MIB type and object identifier.

CR3500 RAID controller (CPQCR.MIB)

Trap types

Rules file

Description

Netcool

severity

cpqCrController1FailureTrap

(1)

1

This event occurs when the primary

controller in the subsystem has
failed.

Critical (5)

cpqCrController1InformationTr
ap (2)

2

This event occurs when the primary
controller in the subsystem has

recovered.

Clear (0)

cpqCrController2FailureTrap

(3)

3

This event occurs when the

secondary controller in the
subsystem has failed.

Critical (5)

cpqCrController2InformationTr
ap (4)

4

This event occurs when the
secondary controller in the

subsystem has recovered.

Clear (0)

cpqCrLogDriveInformationTrap

(5)

5

This event occurs when a RAIDset

has become optimal.

Clear (0)

cpqCrLogDriveFailureTrap (6) 6

This event occurs when a RAIDset

has failed.

Critical (5)

cpqCrLogDriveReconstructTrap

(7)

7

This event occurs when a RAIDset

has started the reconstruction
process.

Minor (3)

cpqCrLogDriveReducedTrap
(8)

8

This event occurs when a RAIDset
has become degraded.

Major (4)

cpqCrLogDriveInitializingTrap
(9)

9

This event occurs when a RAIDset is
initializing.

Minor (3)

cpqCrDiskInformationTrap

(10)

10

This event occurs when a disk drive

has recovered.

Clear (0)

cpqCrDiskFailureTrap (11)

11

This event occurs when a disk drive

fails.

Critical (5)

cpqCrDiskReconstructTrap

(12)

12

This event occurs when a disk

member of a logical drive has
begun the reconstruction process
and will be available for use when

reconstruction is complete.

Minor (3)

Advertising