Product overview, Product description, Product features – HP Insight Management for Tivoli User Manual

Page 7: Prerequisites

Advertising
background image

Product overview 7


Product overview

Product description

HP Insight integration module for Netcool/OMNIbus is a comprehensive solution that provides
infrastructure management across a wide range of operating system platforms. This functionality

enables you to manage HP server and storage hardware, in addition to other enterprise resources,
from a common Netcool/OMNIbus environment. Supported operating platforms for the host include

HP-UX, Sun Solaris, Windows Server® 2000, Windows Server® 2003, Windows Server® 2008,
and Linux. Supported operating platforms for managed systems include HP-UX, Sun Solaris, IBM AIX,
Windows Server® 2000, Windows Server® 2003, Windows Server® 2008, Linux, HP Tru64

UNIX®, and HP OpenVMS.
The HP Insight integration module for Netcool/OMNIbus provides definitions for over 2550

individual notifications defined in its rules file and to correlate nearly 785 SNMP events. These
definitions and rules integrate closely with the Netcool/OMNIbus application using the Mttrapd

probe, enabling HP SNMP events and Fibre Channel Management SNMP events to be identified,
processed, translated, and appear on the Event List.

Product features

•

Integrates into Netcool/OMNIbus v7.2.1 on HP-UX, AIX, Solaris, Linux and Windows®

•

Contains over 2550 SNMP trap definitions for HP ProLiant servers and HP storage platforms

•

Translates and displays SNMP events from all Managed Nodes and Endpoints that have HP

Insight Management Agents installed on Microsoft® Windows NT®, Windows® 2000,

Windows® 2003, Windows® 2008, NetWare, Solaris, Linux, Tru64 UNIX®, and Open VMS

•

Provides predefined rules that identify and correlate nearly 785 HP ProLiant and Fibre Channel

Management SNMP events

•

Provides support up to HP Insight Management Agents version 8.60 for ProLiant servers

Prerequisites

Before uploading the rules and lookup files for Netcool/OMNIbus, be sure that you meet these
additional installation requirements:

•

To access the complete functionality provided with Netcool/OMNIbus, the target Netcool

environment must be fully configured and operational before installation.

•

The Probes, Object Server, and Desktop tools are the only required Netcool/OMNIbus

components.

•

Verify that the correct levels of the IBM Netcool/OMNIbus and related patches have been

installed.

•

SNMP services must be installed and configured on all HP managed systems.

•

The Mttrapd probe must be installed and running.

Advertising