HP Insight Management for Tivoli User Manual

Page 88

Advertising
background image

Appendix B: HP SNMP events 88


Trap types

Rules file

Description

Netcool

severity

sCellEventTrap-09-
50(13602384)

13602384

This event occurs when an enclosure
disappears.

Clear (0)

sCellEventTrap-09-
51(13602385)

13602385

This event occurs when an IO Module
appears.

Clear (0)

sCellEventTrap-09-
52(13602386)

13602386

This event occurs when an IO Module
disappears.

Clear (0)

sCellEventTrap-09-
65(13602405)

13602405

This event occurs when a host operating
system mode changes.

Clear (0)

sCellEventTrap-09-

66(13602406)

13602406

This event occurs when Time is set on a

Storage System.

Clear (0)

sCellEventTrap-09-

67(13602407)

13602407

This event occurs when the LUN of a

Presented Unit changes.

Clear (0)

sCellEventTrap-09-

68(13602408)

13602408

This event occurs when the device

addition policy of a Storage System
changes.

Clear (0)

sCellEventTrap-09-
69(13602409)

13602409

This event occurs when the quiescent state
of a Storage System Virtual Disk changes.

Clear (0)

sCellEventTrap-09-
6a(13602410)

13602410

This event occurs when the
enabled/disabled state of a Storage

System Virtual Disk changes.

Clear (0)

sCellEventTrap-09-

6b(13602411)

13602411

This event occurs when the cache policy

of a Storage System Virtual Disk changes.

Clear (0)

sCellEventTrap-09-

6c(13602412)

13602412

This event occurs when the usage state of

a volume changes.

Clear (0)

sCellEventTrap-09-

6d(13602413)

13602413

This event occurs when the disk failure

protection level of a Disk Group changes.

Clear (0)

sCellEventTrap-09-

6e(13602414)

13602414

This event occurs when the write

protected state of a Derived Unit
changes.

Clear (0)

sCellEventTrap-09-

70(13602416)

13602416

This event occurs when a physical disk

drive experiences numerous
communication failures on a particular
Fibre Channel port.

Minor(3)

sCellEventTrap-09-
71(13602417)

13602417

This event occurs when an HSV300
controller receives a request to shutdown.

Clear (0)

sCellEventTrap-09-
72(13602418)

13602418

This event occurs when an HSV300
controller completes its shutdown

preparations.

Clear (0)

sCellEventTrap-09-

73(13602419)

13602419

This event occurs when the failsafe state

of a Data Replication Group changes.

Clear (0)

sCellEventTrap-09-

74(13602420)

13602420

This event occurs when the mode of a

Data Replication Group changes.

Clear (0)

sCellEventTrap-09-

75(13602421)

13602421

This event occurs when the synchronous

or asynchronous operational state of a
Data Replication Group changes.

Clear (0)

sCellEventTrap-09-

76(13602422)

13602422

This event occurs when the read-only

attribute of a Data Replication Group

Clear (0)