HP Insight Management for Tivoli User Manual

Page 95

Advertising
background image

Appendix B: HP SNMP events 95


Trap types

Rules file

Description

Netcool

severity

2c(13603116)

operation on the Data Replication Source
Storage System or Data Replication
Destination Storage System stalls,

preventing replication processing for the
specified Data Replication Group until
corrective action is performed.

sCellEventTrap-0c-
2d(13603117)

13603117

This event occurs when the Peer Storage
System port name that is incorrectly

associated with a host is deleted from the
specified client object.

Clear (0)

sCellEventTrap-0c-

2e(13603118)

13603118

This event occurs when Insufficient

resources exist to discover additional
remote nodes.

Minor(3)

sCellEventTrap-0c-

2f(13603119)

13603119

This event occurs when sufficient

resources exist to allow discovery of
additional remote nodes.

Clear (0)

sCellEventTrap-0c-

30(13603120)

13603120

This event occurs when a replication

operation on the Data Replication Source
Storage System or Data Replication

Destination Storage System stalls,
preventing replication processing for the
specified Data Replication Group until

corrective action is performed.

Clear (0)

sCellEventTrap-0c-

31(13603121)

13603121

This event occurs when a stalled Full

Copy is restarted.

Clear (0)

sCellEventTrap-0c-

32(13603122)

13603122

This event occurs when the Data

Replication Path between this Storage
System and the Peer Storage System

closes because the host port connection
failed.

Critical(5)

sCellEventTrap-0c-

33(13603123)

13603123

This event occurs when the Data

Replication Path between this Storage
System and the Peer Storage System

closes because the link or the Storage
System is unresponsive.

Critical(5)

sCellEventTrap-0c-
34(13603124)

13603124

This event occurs when the Data
Replication Path between this Storage

System and the Peer Storage System
closes due to slow response on the
connection between the specified host

port and the Peer Storage System.

Critical(5)

sCellEventTrap-0c-

35(13603125)

13603125

This event occurs when the Data

Replication Path between this Storage
System and the Peer Storage System
closes because a Data Replication Group

configuration change lock is not released
in a timely manner.

Minor(3)

sCellEventTrap-0c-

36(13603126)

13603126

This event occurs when the Data

Replication Path between this Storage
System and the Peer Storage System

closes due to thrashing of the connection

Critical(5)

Advertising