Appendix B: HP SNMP events 86


Trap types

Rules file

Description

Netcool

severity

removed from the power supply.

sCellEventTrap-09-

29(13602345)

13602345

This event occurs when an HSV300

controller 2 blower or power supply
assembly is reinstalled or AC power is
restored to the power supply.

Clear (0)

sCellEventTrap-09-
2a(13602346)

13602346

This event occurs when an HSV300
controller 1 blower or power supply is

running slower than the lowest acceptable
speed.

Critical(5)

sCellEventTrap-09-
2b(13602347)

13602347

This event occurs when an HSV300
controller 2 blower or power supply is

running slower than the lowest acceptable
speed.

Critical(5)

sCellEventTrap-09-

2c(13602348)


13602348

This event occurs when an HSV300

controller battery assembly transitions to
the Battery System Hold-up Time

is zero hour state.

Minor(3)

sCellEventTrap-09-
2d(13602349)

13602349

This event occurs when the resource
availability state of a volume transitions to

the INSUFFICIENT state.

Critical(5)

sCellEventTrap-09-

2e(13602350)

13602350

This event occurs when an HSV300

controller rejects a login attempt.

Clear (0)

sCellEventTrap-09-

2f(13602351)

13602351

This event occurs when an HSV300

controller processes a Storage System
Management Interface command with the
result of an unsuccessful return code.

Clear (0)

sCellEventTrap-09-

30(13602352)

13602352

This event occurs when an HSV300

controller updates the physical disk drive
map for a loop pair.

Clear (0)

sCellEventTrap-09-

31(13602353)

13602353

This event occurs when a physical disk

drive transitionsd to DEGRADED state.

Critical(5)

sCellEventTrap-09-

32(13602354)

13602354

This event occurs when a physical disk

drive transitionsd to FAILED state.

Critical(5)

sCellEventTrap-09-
33(13602355)

13602355

This event occurs when a Derived Unit is
created.

Clear (0)

sCellEventTrap-09-
34(13602356)

13602356

This event occurs when a logical disk is
created.

Clear (0)

sCellEventTrap-09-
35(13602357)

13602357

This event occurs when a Disk Group is
created.

Clear (0)

sCellEventTrap-09-

36(13602358)

13602358

This event occurs when a physical disk

drive is discovered.

Clear (0)

sCellEventTrap-09-

37(13602359)

13602359

This event occurs when a Presented Unit is

created.

Clear (0)

sCellEventTrap-09-

38(13602360)

13602360

This event occurs when a Storage System

Host Path is created.

Clear (0)

sCellEventTrap-09-

39(13602361)

13602361

This event occurs when a Storage System

Virtual Disk is created.

Clear (0)