HP Insight Management for Tivoli User Manual

Page 82

Advertising
background image

Appendix B: HP SNMP events 82


Trap types

Rules file

Description

Netcool

severity

sCellEventTrap-06-
5d(13601629)

13601629

This event occurs when an HSV300
controller detects a change in an

enclosure fan module 2 condition.

Clear (0)

sCellEventTrap-06-

5e(13601630)

13601630

This event occurs when an HSV300

controller detects a change in the
enclosure A-side link module condition.

Clear (0)

sCellEventTrap-06-

5f(13601631)

13601631

This event occurs when an HSV300

controller detects a change in the
enclosure B-side link moduls condition.

Clear (0)

sCellEventTrap-06-

60(13601632)

13601632

This event occurs when an HSV300

controller detects a change in the
enclosure A-side link module transceiver
condition.

Clear (0)

sCellEventTrap-06-
61(13601633)

13601633

This event occurs when an HSV300
controller detects a change in the

enclosure B-side link module transceiver
condition.

Clear (0)

sCellEventTrap-06-

62(13601634)

13601634

This event occurs when an HSV300

controller detects a change in the
enclosure A-side link module

alphanumeric display.

Clear (0)

sCellEventTrap-06-

63(13601635)

13601635

This event occurs when an HSV300

controller detects a change in the
enclosure B-side link module

alphanumeric display.

Clear (0)

sCellEventTrap-06-

64(13601636)

13601636

This event occurs when an HSV300

controller detects a change in the
enclosure A-side link module temperature
sensor.

Clear (0)

sCellEventTrap-06-
65(13601637)

13601637

This event occurs when an HSV300
controller detects a change in the

enclosure B-side link module temperature
sensor.

Clear (0)

sCellEventTrap-06-
66(13601638)

13601638

This event occurs when an HSV300
controller detects a change in the

enclosure midplane condition.

Clear (0)

sCellEventTrap-06-

67(13601639)

13601639

This event occurs when an HSV300

controller detects a change in the
enclosure midplane temperature sensor
condition.

Clear (0)

sCellEventTrap-06-
68(13601640)

13601640

This event occurs when an HSV300
controller detects only one port of an

enclosure device.

Critical(5)

sCellEventTrap-06-

69(13601641)

13601641

This event occurs when a previously

reported enclosure device with only one
port is corrected and redundancy is

restored.

Clear (0)

sCellEventTrap-07-

00(13601792)

13601792

This event occurs when Allocation of a

Virtual Disk stalls due to insufficient space

Minor(3)

Advertising