HP Insight Management for Tivoli User Manual

Page 35

Advertising
background image

Appendix B: HP SNMP events 35


Trap types

Rules file

Description

Netcool

severity

cpqHe3ThermalTempOk (6019) 6019

This event occurs when the server
temperature has returned to the

normal operating range.

Clear (0)

cpqHe3ThermalSystemFanFailed

(6020)

This event occurs when a required

system fan is not operating
normally.

cpqHeThermalDegradedAction:c
ontinue

cpqHeThermalDegra
dedAction.2

Major (4)

cpqHeThermalDegradedAction:s
hutdown

cpqHeThermalDegra
dedAction.3

Major (4)

cpqHe3ThermalSystemFanDegra
ded (6021)

6021

This event occurs when an optional
system fan is not operating

normally.

Major (4)

cpqHe3ThermalSystemFanOk

(6022)

6022

This event occurs when any of the

previously non-operational system
fans have returned to normal

operation.

Clear (0)

cpqHe3ThermalCpuFanFailed

(6023)

6023

This event occurs when a

processor fan is not operating
normally.

Critical (5)

cpqHe3ThermalCpuFanOk

(6024)

6024

This event occurs when any of the

previously non-operational
processor fans have returned to

normal operation.

Clear (0)

cpqHe3AsrConfirmation (6025) 6025

This event occurs when the server

has previously been shutdown by
the Automatic Server Recovery

(ASR) feature and has just become
operational again.

Minor (3)

cpqHe3ThermalConfirmation

(6026)

6026

This event occurs when the server

has previously been shutdown
because a thermal anomaly on the

server and has just become
operational again.

Minor (3)

cpqHe3PostError (6027)

6027

This event occurs when Power On
Self-Test (POST) errors occurred

during the server restart process.

Minor (3)

cpqHe3FltTolPwrSupplyDegrade

d (6028)

6028

This event occurs when the fault

tolerant power supply subsystem
condition has been set to
Degraded.

Major (4)

cpqHe3CorrMemReplaceMemM

odule (6029)

6029

This event occurs when a

correctable memory log entry
indicates a memory module must

be replaced.

Minor (3)

cpqHe3FltTolPowerRedundancyL

ost (6032)

6032

This event occurs when the fault

tolerant power supplies have lost
redundancy for the specified

chassis.

Major (4)

Advertising