Server health features (cpqhlth.mib) – HP Insight Management for Tivoli User Manual

Page 34

Advertising
background image

Appendix B: HP SNMP events 34


Trap types

Rules file

Description

Netcool

severity

cpqSasLogDrvStatusChange
(5023)

—

This event occurs when the status
of a SAS or SATA logical drive

changes.

—

CpqSasLogDrvStatus:ok

CpqSasLogDrvStatus.

2

—

Clear (0)

CpqSasLogDrvStatus:degraded CpqSasLogDrvStatus.

3

—

Minor (3)

CpqSasLogDrvStatus:rebuilding CpqSasLogDrvStatus.

4

—

Minor (3)

CpqSasLogDrvStatus:failed

CpqSasLogDrvStatus.

5

—

Critical (5)

CpqSasLogDrvStatus:offline

CpqSasLogDrvStatus.
6

—

Critical (5)

CpqSas2TapeDrvStatusChange
(5025)

—

This event occurs when the status
of a SAS tape drive changes.

—

cpqSasTapeDrvStatus: ok

cpqSasTapeDrvStatus
.2

—

Clear (0)

cpqSasTapeDrvStatus: offline

cpqSasTapeDrvStatus

.3

—

Critical (5)

Server health features (CPQHLTH.MIB)

Trap types

Rules file

Description

Netcool

severity

cpqHe3CorrectableMemoryLogD

isabled (6016)

—

This event occurs when the

frequency of correctable memory
errors is so high that the error
tracking logic has been

temporarily disabled.

—

cpqHeCorrMemLogStatus:notSup

ported

cpqHeCorrMemLogSt

atus.2

—

Minor (3)

cpqHeCorrMemLogStatus:disabl

ed

cpqHeCorrMemLogSt

atus.3

—

Major (4)

cpqHeCorrMemLogStatus:enable

d

cpqHeCorrMemLogSt

atus.4

—

Clear (0)

cpqHe3ThermalTempFailed

(6017)

6017

This event occurs when the

temperature status has been set to
fail.

Critical (5)

cpqHe3ThermalTempDegraded

(6018)

—

This event occurs when the server's

temperature is outside of the
normal operating range.

—

cpqHeThermalDegradedAction:c

ontinue

cpqHeThermalDegra

dedAction.2

—

Major (4)

cpqHeThermalDegradedAction:s

hutdown

cpqHeThermalDegra

dedAction.3

—

Major (4)

Advertising