If PVOL has non-reflected data in PAIR state:

Behavior of first pairsplit at T0

Behavior of OLD pairsplit at T0

PVOL_PAIR from/to SVOL_PAIR(WD)

T0 PVOL_PAIR from/to SVOL_PAIR(WD)

PVOL_PSUS from/to SVOL_COPY(WE)

T1: PVOL_COPY from/to SVOL_COPY(WD)

PVOL_PSUS from/to SVOL_SSUS(WE)

T2: PVOL_PSUS from/to SVOL_SSUS(WE)

If PVOL has been reflected all data to SVOL in PAIR state:

Behavior of First pairsplit at T0

Behavior of OLD pairsplit at T0

PVOL_PAIR from/to SVOL_PAIR(WD)

T0: PVOL_PAIR from/to SVOL_PAIR(WD)

PVOL_PSUS from/to SVOL_SSUS(WE)

T1: PVOL_PSUS from/to SVOL_SSUS(WE)

The state changes for paircreate -split are:

Behavior of First paircreate -split at T0

Behavior of OLD paircreate -split at T0

SMPL from/to SMPL

T0: SMPL from/to SMPL

PVOL_PSUS from/to SVOL_COPY(WE)

T1: PVOL_COPY from/to SVOL_COPY(WD)

PVOL_PSUS from/to SVOL_SSUS(WE)

T2: PVOL_PSUS from/to SVOL_SSUS(WE)

If you attempt the pairevtwait -s psus in PVOL_PSUS & SVOL_COPY state, then pairevtwait
will return immediately even if the S-VOL is still in SVOL_COPY state because PVOL is already
in PVOL_PSUS state. If you want to wait the "SVOL_SSUS" state, and then you must check the
status of the S-VOL becomes "SVOL_PSUS" via the return code using pairvolchk -ss command
on SVOL side or pairvolchk -ss -c command on PVOL side. Or you can use pairevtwait -ss
ssus on both PVOL and SVOL, pairevtwait -ss ssus -l on SVOL locally.

If you attempt the pairresync -restore or pairsplit -S in PVOL_PSUS & SVOL_COPY state, then
Business Copy will reject this command due to unable to perform. In this case, you need to
wait until the S-VOL state becomes SVOL_SSUS.

Table 34 Pair status versus Snapshot commands

Snapshot Command

Pair Status

pairresync

pairsplit

paircreate

Resync

-S option

-C option

-E option

-split

No -split

Rejected

Acceptable

Rejected

Rejected

Rejected

Accepted 2

SMPL

1

Acceptable

Rejected

Rejected

Rejected

Rejected

Acceptable

COPY
RCPY

2

Acceptable

Accepted 1

Accepted 4

Rejected

Accepted*4

Acceptable

PAIR

3

Accepted* 2

Accepted 1

Acceptable

Rejected

Acceptable

Rejected

PSUS
(PFUS)

4

Accepted* 2

Accepted 1

Rejected

Acceptable

Rejected

Rejected

PSUE

5

Accepted*: A command is accepted and issued; whether this command is executed or not depends
on the microcode version of the RAID storage system.