Table 92 SSB codes that are returned by raidcom add rcu command (continued)

raidcom add rcu

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

Cable is not connected correctly.

Port is specified incorrectly.

The operation cannot be done because the microcode is being
changed.

8004

2E11

Async

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

9400

2E11

Executing

CMDRJE

The serial number, the product ID, or the SSID of the target
storage system is incorrect.

3000

2E20

Async

Get Command Status

The specified CU number is not defined, or an LDEV is not
defined under the CU number.

7101

2E21

Async

Get Command Status

The specified RCU is already registered to another product ID.

3001

2E22

Async

Get Command Status

The operation cannot be performed due to one of the following
reasons:

3002

2E22

Async

Get Command Status

The number of RCUs registered in MCU or RCU is more than
four.

The number of RCUs registered in the system is more than
64 in the case of specifying the cu free.

The specified SSID is already registered to another RCU.

3300

2E22

Async

Get Command Status

The specified RCU is cannot be registered because there is no
free RCU.

3000

2E23

Async

Get Command Status

The operation cannot be done because the number of paths
becomes less than the least path number.

3101

2E23

Async

Get Command Status

The port attribute is not Initiator (MCU).

840A

2E30

Executing

CMDRJE

Command cannot be executed because the RCU identification
code of a path is invalid.

3001

2E31

Async

Get Command Status

The operation cannot be performed because the remote storage
system does not support the path between CUs.

3002

2E31

Async

Get Command Status

Command cannot be executed because the serial number is not
unified in the specified path.

3101

2E31

Async

Get Command Status

The command cannot be accepted because the DKC is busy.
After a while, execute the same command.

00EE

2ED6

Executing

CMDRJE

An internal error occurred.

3005

2ED6

Async

Get Command Status

Call HP Technical Support.

The value of SSID on the remote storage system is invalid.

3300

2ED6

Executing

CMDRJE

The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.

3002

2EF3

Executing

CMDRJE

Error messages and error codes

281