background image

Table 59 SSB codes that are returned by raidcom modify port -security _switch command (continued)

raidcom modify port -security _switch

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The other than "P-to-P (point to point)" cannot be specified when
specifying a topology of the package for Fibre Channel over
Ethernet.

05A7

B955

Executing

CMDRJE

The command device being used at the local RAID Manager
exists under the port.

1039

B955

Executing

CMDRJE

The program product is not installed.

104F

B955

Executing

CMDRJE

Invalid host speed is set for the 4Gbps fibre adapter. The
available host speeds are AUTO, 1G, 2G, and 4G only.

113D

B955

Executing

CMDRJE

Invalid host speed is set for the 8Gbps fibre adapter. The
available host speeds are AUTO, 2G, 4G, and 8G only.

113F

B955

Executing

CMDRJE

The other than "10G" cannot be specified when specifying a
host speed of the package for Fibre Channel over Ethernet.

11A5

B955

Executing

CMDRJE

Table 60 SSB codes that are returned by raidcom add ldev command

raidcom add ldev

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

It exceeds the range of LDEV number.

0000

2E00

Executing

CMDRJE

Cannot create because the specified capacity is invalid.

0002

2E00

Executing

CMDRJE

SSID is not in the effective range.

0003

2E00

Executing

CMDRJE

The value of specified emulation type is invalid.

000D

2E00

Executing

CMDRJE

The specified emulation type is not supported in this command.

000E

2E00

Executing

CMDRJE

A Thin Provisioning virtual volume cannot be created because
the specified LDEV number is already used.

0010

2E00

Executing

CMDRJE

There are not enough cache management devices.

0013

2E00

Asynchronous

Get Command Status

Cannot create because the specified capacity is invalid.

0014

2E00

Asynchronous

Get Command Status

The capacity in the case of specifying a emulation type of the
mainframe series must be dividable by the cylinder.

0019

2E00

Executing

CMDRJE

The capacity when 3390-V emulation type is specified must be
divisible by page unit.

001A

2E00

Executing

CMDRJE

When you specify emulation type for open system, you cannot
specify the size by the cylinder.

001C

2E00

Executing

CMDRJE

A volume for online data migration cannot be created because
the specified value of capacity (LBA) is not the maximum.

0025

2E00

Executing

Async

CMDRJE

Get Command Status

The capacity must be specified because LDEVs are in the parity
group (or the external volume group).

0026

2E00

Executing

CMDRJE

The capacity must be specified.

0027

2E00

Executing

CMDRJE

The emulation type of the mainframe cannot be specified
because the virtual volume is set for the specified LDEV.

002D

2E00

Async