HP XP7 Storage User Manual

Page 264

Advertising
background image

Table 81 SSB codes returned by raidcom add snapshot (continued)

raidcom add snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

A Fast Snap or Snapshot pair cannot be created because
the Thin Provisioning V-VOL in capacity expanding is
specified as the P-VOL of a Fast Snap or Snapshot pair.

0041

2E10

Executing

CMDRJE

A Fast Snap or Snapshot pair cannot be created because
the Thin Provisioning V-VOL that is discharging zero data
is specified as the P-VOL of a Fast Snap or Snapshot pair.

0042

2E10

Executing

CMDRJE

A pair cannot be created because the P-VOL of a
Continuous Access Synchronous pair is specified as the
S-VOL of a Fast Snap or Snapshot pair.

0045

2E10

Executing

CMDRJE

A pair cannot be created because the S-VOL of a
Continuous Access Synchronous pair is specified as the
S-VOL of a Fast Snap or Snapshot pair.

0046

2E10

Executing

CMDRJE

The command ends abnormally because the Business Copy
pair is being resynchronized when the volume is shared

0049

2E10

Executing

CMDRJE

between the P-VOL of a Fast Snap/Snapshot pair and the
P-VOL of a Business Copy pair.

The command ends abnormally because the Business Copy
pair status is other than PSUS when the volume is shared

004A

2E10

Executing

CMDRJE

between P-VOL of a Fast Snap/Snapshot pair and the
S-VOL of a Business Copy pair.

The operation cannot be performed because the Quick
Restore is being operated on the specified Business Copy
P-VOL.

004E

2E10

Executing

CMDRJE

A pair operations cannot be performed because the volume
using 2 mirrors included in the 3DC multi-target

0051

2E10

Executing

CMDRJE

configuration, 3DC cascade configuration or 3DC delta
resync configuration by the 3 Continuous Access Journal
sites is specified.

A Fast Snap pair cannot be created because the pair status
of all Fast Snap pairs sharing the specified P-VOL is PSUE.

0052

2E10

Executing

CMDRJE

A Fast Snap pair cannot be operated because the virtual
storage machine of the P-VOL is different from the virtual
storage machine of the S-VOL.

005B

2E10

Executing

CMDRJE

A Fast Snap pair cannot be operated because changing
the model and the serial number in the virtual storage
machine of the specified P-VOL is in progress.

005C

2E10

Executing

CMDRJE

A Fast Snap pair cannot be operated because changing
the model and the serial number in the virtual storage
machine of the specified S-VOL is in progress.

005D

2E10

Executing

CMDRJE

A Fast Snap or Snapshot pair with the specified consistency
group number cannot be created due to one of the
following reasons:

2300

2E10

Executing

CMDRJE

The specified consistency group number is used by the
Business Copy.

The number of pairs that can be defined in a consistency
group exceeds the maximum.

The pair created by using the same P-VOL already exists
in the specified consistency group.

264 Troubleshooting