Table 100 SSB codes that are returned by raidcom modify port -port_speed command (continued)

raidcom modify port -port_speed

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The other than "P-to-P (point to point)" cannot be specified when
specifying a topology of the package for Fibre Channel over
Ethernet.

05A7

B955

Executing

CMDRJE

The command device being used at the local RAID Manager
exists under the port.

1039

B955

Executing

CMDRJE

The program product is not installed.

104F

B955

Executing

CMDRJE

Invalid host speed is set for 4Gbps fibre adapter. The available
host speeds are AUTO, 1G, 2G, and 4G only.

113D

B955

Executing

CMDRJE

Invalid host speed is set for 8Gbps Fibre Adapter. The available
host speeds are AUTO, 2G, 4G, and 8G only.

113F

B955

Executing

CMDRJE

The other than "10G" cannot be specified when specifying a
host speed of the package for Fibre Channel over Ethernet.

11A5

B955

Executing

CMDRJE

Invalid host speed is set for 16Gbps Fibre Adapter. The available
host speeds are AUTO, 2G, 4G, and 8G only.

11AE

B955

Executing

CMDRJE

Topology FC-AL and 16G as the host speed are not supported
for the 16Gbps fibre adapter.

12AF

B955

Executing

CMDRJE

Table 101 SSB codes that are returned by raidcom modify port -port_attribute command

raidcom modify port -port_attribute

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

Invalid package

8404

2E00

Executing

CMDRJE

The operation cannot be done because another application, for
example Remote Web Console and SVP, is used.

8001

2E10

Executing

CMDRJE

The specified port is blocked.

8400

2E10

Executing

CMDRJE

There is a pair for Continuous Access Synchronous/Continuous
Access Journal that is used the specified port.

8402

2E10

Executing

CMDRJE

There is a pair for Continuous Access Synchronous/Continuous
Access Journal that is used the specified port.

8403

2E10

Executing

CMDRJE

The storage system is in the state of start-up. Wait for a while,
then retry the operation.

800D

2E11

Executing

CMDRJE

The specified port is not installed.

8400

2E20

Executing

CMDRJE

There is a path for Continuous Access Synchronous/Continuous
Access Journal in the specified port.

8403

2E30

Executing

CMDRJE

There is an external VOL path in the specified port.

8406

2E30

Executing

CMDRJE

There is a path for Continuous Access Synchronous/Continuous
Access Journal in the specified port.

8407

2E30

Executing

CMDRJE

There is a path for Continuous Access Synchronous/Continuous
Access Journal in the specified port.

8408

2E30

Executing

CMDRJE

An LU path has been defined.

8409

2E30

Executing

CMDRJE

An internal error occurred.

84FC

2ED0

Executing

CMDRJE

286 Troubleshooting

Advertising