CL1-B FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b01

CL2-A FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b10

CL2-B FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b11

CL3-A FIBRE TAR AUT E8 N FCAL N 0 64539 50060e8006fc1b20

CL3-B FIBRE TAR AUT E0 N FCAL N 0 64539 50060e8006fc1b21

CL4-A FIBRE TAR AUT D6 N FCAL N 0 64539 50060e8006fc1b30

CL4-B FIBRE TAR AUT D2 N FCAL N 0 64539 50060e8006fc1b31

CL5-A FIBRE TAR AUT E4 N FCAL N 0 64539 50060e8006fc1b40

CL5-B FIBRE TAR AUT DC N FCAL N 0 64539 50060e8006fc1b41

CL6-A FIBRE TAR AUT D5 N FCAL N 0 64539 50060e8006fc1b50

CL6-B FIBRE TAR AUT D1 N FCAL N 0 64539 50060e8006fc1b51

CL7-A FIBRE ELUN AUT E2 N FCAL N 0 64539 50060e8006fc1b60

CL7-B FIBRE ELUN AUT DA N FCAL N 0 64539 50060e8006fc1b61

CL8-A FIBRE TAR AUT D4 N FCAL N 0 64539 50060e8006fc1b70

CL8-B FIBRE TAR AUT CE N FCAL N 0 64539 50060e8006fc1b71

C:\HORCM\etc>raidcom -zt 4_no_port.bat -load portcnf_27.dat -checkmode precheck

C:\HORCM\etc>raidcom add path -path_grp 1 -port CL1-C -external_wwn 50060e80,06fc4180

raidcom: PORT(2) does not exist as status is [2] on UnitID# 0.

raidcom_#2 : [EX_CTXCHK] Context Check error

C:\HORCM\etc>raidcom add path -path_grp 1 -port CL1-D -external_wwn 50060e80,06fc4190

raidcom: PORT(3) does not exist as status is [2] on UnitID# 0.

raidcom_#3 : [EX_CTXCHK] Context Check error

C:\HORCM\etc>raidcom add path -path_grp 1 -port CL1-E -external_wwn 50060e80,06fc41a0

raidcom: PORT(4) does not exist as status is [2] on UnitID# 0.

raidcom_#4 : [EX_CTXCHK] Context Check error

Host group check

The check is performed from the following perspective. Note that checking for an attribute of host
group, or for a name of host group is not executed.

Check with the attribute setting

It is checked whether the operation is performed for the existing host group. If the host group does
not exist, an error is detected.

If it is not clear whether the target port or host group exists (if the target port or host group
information does not exist in the configuration definition file), the error is not detected.

The command as the target of the check is shown below.

raidcom modify host_grp -port <port#> [<host group name>] -host_mode <host mode>
[-host_mode_opt <host mode option> … ]

raidcom add hba_wwn -port <port#> [<host group name>] -hba_wwn <WWN strings>

raidcom delete hba_wwn -port <port#> [<host group name>] -hba_wwn <WWN strings>

raidcom set hba_wwn -port <port#>[<host group name>] -hba_wwn <WWN strings>
-wwn_nickname <WWN Nickname>

raidcom reset hba_wwn -port <port#>[<host group name>] -hba_wwn <WWN strings>

raidcom add lun -port <port#> [<host group name>] {-ldev_id <ldev#> [-lun_id<lun#>] |
-grp_opt <group option> -device_grp_name <device group name> [<device name>]}

raidcom delete lun -port <port#> [<host group name>] {-lun_id <lun#> | -ldev_id <ldev#> |
-grp_opt <group option> -device_grp_name <device group name> [<device name>]}