The electrical system to which the unit is

connected must be equipped with a 20A

max automatic bipolar circuit breaker.

The minimum distance between the

contacts must be 3mm (0.1in). The circuit

breaker must be provided with protection

against the fault current towards the

ground (differential) and the overcurrent

(magnetothermal).

J2

L

N

a

Earth

Neutral

Phase

Fig. 13

Connect the power supply cables to the J2 terminal

as described in the table.

CONNECTION OF THE POWER SUPPLY LINE

Colour

Terminals

Power supply 24Vac
Defined by the installer

24Vac

Defined by the installer

24Vac

Yellow/Green

GND

Power supply 230Vac
Blue

N (Neutral)

Brown

L (Phase)

Yellow/Green

GND

Power supply 120Vac
Blue

N (Neutral)

Brown

L (Phase)

Yellow/Green

GND

Tab. 1

Use a Class 2 listed UL tranformer,

compliant with the Standards in force, only

for products marked UL, powered at 24Vac.

To connect the power supply line use the

appropriate junction-box (UPTJBUL). For

further information, refer to the product

use and installation manual.