10 setting the configuration check mode (dip 1), 11 baud rate configuration, 12 setting of the serial communication lines – Videotec ULISSE COMPACT User Manual
Page 23
Instruc
tions manual - English - EN
23
MNVCUCZ_1351_EN
7.1.10 Setting the configuration check
mode (DIP 1)
SW 1=ON: Display Configuration. To be used only to
verify the configuration at the end of the setting. To
be used only to verify the configuration at the end of
the setting. During normal operation make sure the
lever is on OFF (SW 1=OFF).
7.1.11 Baud rate configuration
To set the baud rate operate on DIP 1.
Dip-switches 4, 3 and 2 are used to set the
communication rate of the device according to the
table below.
BAUD RATE CONFIGURATION (DIP 1)
Description
SW 1
SW 2
SW 3
SW 4
SW 5-6-7-8
Configur
ation
Baud rate
selection
–
ON ON ON –
38400 baud
–
OFF ON ON –
19200 baud
–
ON OFF ON –
9600 baud
–
OFF OFF ON –
4800 baud
–
ON ON OFF –
2400 baud
–
OFF ON OFF –
1200 baud
–
ON OFF OFF –
600 baud
–
OFF OFF OFF –
300 baud
Configurations
display
ON –
–
–
–
Display ena-
bled
OFF –
–
–
–
Display disa-
bled
Tab. 5
7.1.12 Setting of the serial
communication lines
To set the serial communication lines operate on
DIP 1.
The product is provided with the following serial
communication lines:
• RS-485: 2 lines
The serial lines configuration must be carried on
through the following dip-switches:
• DIP 1: SW 5-SW 6
SETTING OF THE SERIAL COMMUNICATION LINES (DIP
1)
Description
SW 1-2-3-4
SW 5
SW 6
SW 7-8
Configur
ation (see
rela
ted chapt
ers)
Serial line
–
ON ON –
Two-way RS-485 TX/
RX line
–
OFF ON –
Line RS-485-1 reception,
line RS-485-2 repetition
–
ON OFF –
Two-way RS-422 line
–
OFF OFF –
One-way RS-485 line
Tab. 6