7.1.10 Setting the configuration check

mode (DIP 1)

SW 1=ON: Display Configuration. To be used only to

verify the configuration at the end of the setting. To

be used only to verify the configuration at the end of

the setting. During normal operation make sure the

lever is on OFF (SW 1=OFF).

7.1.11 Baud rate configuration

To set the baud rate operate on DIP 1.
Dip-switches 4, 3 and 2 are used to set the

communication rate of the device according to the

table below.

BAUD RATE CONFIGURATION (DIP 1)

Description

SW 1

SW 2

SW 3

SW 4

SW 5-6-7-8

Configur

ation

Baud rate

selection

ON ON ON –

38400 baud

OFF ON ON –

19200 baud

ON OFF ON –

9600 baud

OFF OFF ON –

4800 baud

ON ON OFF –

2400 baud

OFF ON OFF –

1200 baud

ON OFF OFF –

600 baud

OFF OFF OFF –

300 baud

Configurations

display

ON –

Display ena-

bled

OFF –

Display disa-

bled

Tab. 5

7.1.12 Setting of the serial

communication lines

To set the serial communication lines operate on

DIP 1.
The product is provided with the following serial

communication lines:
• RS-485: 2 lines
The serial lines configuration must be carried on

through the following dip-switches:
• DIP 1: SW 5-SW 6

SETTING OF THE SERIAL COMMUNICATION LINES (DIP

1)

Description

SW 1-2-3-4

SW 5

SW 6

SW 7-8

Configur

ation (see

rela

ted chapt

ers)

Serial line

ON ON –

Two-way RS-485 TX/

RX line

OFF ON –

Line RS-485-1 reception,

line RS-485-2 repetition

ON OFF –

Two-way RS-422 line

OFF OFF –

One-way RS-485 line

Tab. 6