7.1.4 Video cable connection

The installation is type CDS (Cable

Distribution System), do not connect it to

SELV circuits.

In order to reduce the risk of fire, only use

cable sizes greater than or equal to 26AWG

(0.13mm²).

The content of this chapter does not apply

to the versions with digital video encoder.

The video signal is present on connectors J5 and J7 of

the board. Only use one connector.
Connector J5: Connect the screen and the central

cable to terminals GND and CVBS respectively.
Connector J7: Connect the coaxial cable to the BNC

connector (not supplied) and then connect it to

connector J7.
The terminals accept cables with sections between

1.5mm² (AWG16) and 0,5mm² (AWG30).

VIDEO OUT

J7

CVBS

J5

GND

RS485-1

SGND

A

B

RS485-2

SGND

A B

Fig. 14

7.1.5 Telemetry line connections

The installation is type TNV-1, do not

connect it to SELV circuits.

In order to reduce the risk of fire, only use

cable sizes greater than or equal to 26AWG

(0.13mm²).

The content of this chapter does not apply

to the versions with digital video encoder.

The product is supplied with 2 RS-485 serial

communication lines.

TELEMETRY LINE CONNECTIONS

Serial line

Terminal

Description

RS-485-1

A (+)

RS-485 line (1)

B (-)

RS-485 line (1)

SGND

RS-485-1 line

reference

RS-485-2

A (+)

RS-485 line (2)

B (-)

RS-485 line (2)

SGND

RS-485-2 line

reference

Tab. 2

The lines can be configured in various ways according

to the positions of dip-switches 5 and 6 on the Serial

(DIP 1) of the CPU board (7.1.12 Setting of the serial

communication lines, page 23).

VIDEO OUT

J7

CVBS

J5

GND

RS485-1

SGND

A

B

RS485-2

SGND

A B

Fig. 15