Videotec ULISSE COMPACT User Manual

Page 65

Advertising
background image

Instruc

tions manual - English - EN

65

MNVCUCZ_1351_EN

PROBLEM

Error E7-PRST. NOT

CONFIGURED.

CAUSE

Recalling of a non programmed

preset.

SOLUTION

Seek assistance.

PROBLEM

Error E8-TOUR NOT

CONFIGURED.

CAUSE

Recalling of a non configured Tour.

SOLUTION

Save the Tour using the relative

control (11.6 Recalling a pattern

(Tour), page 56).

PROBLEM

Error E9-TEMP. TOO LOW.

CAUSE

The environment temperature is

too low.

SOLUTION

The movements of the P&T unit

is blocked to prevent mechanical

damage.

PROBLEM

Alarm AL6 :WATER LEVEL LOW

CAUSE

Low wiper liquid level.

SOLUTION

Fill the tank of the pump using the

suitable wiper liquid.

PROBLEM

The video is not viewed

correctly using the version with

H.264/AV encoder.

CAUSE

The encoder parameters are

incorrect.

SOLUTION

Make sure that the Input

Deinterlacing item is set to OFF in

the Chamber Parameter page of

the web interface (9.3.12 Camera

Parameters, page 53). The Input

Format item must be set on

Composite PAL or Composite NTSC,

depending on the camera installed

on the unit.

Advertising