12 Maintaining and
cleaning

12.1 Maintaining

Maintenance must be carried out by

personnel trained to operate on electrical

circuits.

12.1.1 Firmware updating

The H.264 encoder firmware can be

upgraded directly from the web interface.

If necessary, it is possible to update the pan & tilt

firmware; for further information please contact

Videotec.
The firmware updating operation can be done on

site, using the cable supplied with the pan & tilt, or

in remote mode (only MACRO/VIDEOTEC and PELCO

D protocols) using a 485 serial – USB converter (not

supplied).

12.1.2 Replacing the fuses

If necessary it is possible to save the pan & tilt

configuration; for further information contact

Videotec.
The saving/resetting operation can be done on site,

using the cable supplied with the pan & tilt or in

remote mode (only MACRO/VIDEOTEC and PELCO D

protocols), using the serial 485 – USB converter (not

supplied).

12.1.3 Fuses replacement

For continued protection against risk of fire,

replace only with same type and rating of

fuse. Fuses must be replaced only by service

personnel.

There are two preset fuses on the connection board.

FUS1

FUS2

Fig. 124

Their sizes are related to the power supply voltage.

FUSES REPLACEMENT

Voltage

Fuse F1

Fuse F2

24Vac, 50/60Hz

T 4A L 250V 5x20

T 6.3A H 250V 5x20

120Vac, 50/60Hz

T 4A L 250V 5x20

T 4A H 250V 5x20

230Vac, 50/60Hz

T 4A L 250V 5x20

T 2A H 250V 5x20

Tab. 11