Videotec ULISSE COMPACT User Manual

Page 64

Advertising
background image

EN - English - I

nstruc

tions manual

64

MNVCUCZ_1351_EN

PROBLEM

During start-up the pan & tilt is

disabled and the following type

of message is shown:

Address : 1

DE-ICE PROCEDURE

IN PROGRESS…

REMAINING MINUTES:59

CAUSE

The environment temperature is

too low.

SOLUTION

Wait until the end of the pre-heating

procedure. If the air temperature is

too low the unit will remain disabled

and the following message will be

shown:

Address : 1

DE-ICE PROCEDURE

------------------------

SYSTEM BLOCKED

TEMPERATURE TOO LOW

------------------------

PROBLEM

Error E1-AUTOPAN WITHOUT

LIMITS.

CAUSE

The two presets used as limits have

not been programmed.

SOLUTION

Program the two presets and then

update the Autopan configuration

menu (11.2 Saving the current

position (Preset), page 55 and

9.1.10.7 Autopan Menu, page 40).

PROBLEM

Error E2-WIPER BLOCKED.

CAUSE

The wiper is either jammed or

broken.

SOLUTION

Check that the wiper is free to

move; if the problem persists, seek

assistance.

PROBLEM

Error E3-PATROL WITHOUT

PRESET or error E4-PATROL, 1

PRESET ONLY.

CAUSE

The presets have not been

programmed.

SOLUTION

Program two or more presets and

then update the Patrol configuration

menu (11.2 Saving the current

position (Preset), page 55 and

9.1.10.6 Patrol Menu, page 40).

PROBLEM

Error E5-IR TEMP. TOO HIGH or

error E6-IR FAULT.

CAUSE

The infrared illuminator is not

working properly.

SOLUTION

Save the preset using the relative

control (11.2 Saving the current

position (Preset), page 55).

Advertising