Acer Altos G901 User Manual

Page 153

Advertising
background image

137

FRB-2 Policy

Selects an action to implement
when an FRB-2 failure occurs, that
is whether to disable the BSP (Boot
Strap Processor) or not.

An FRB-2 failure occurs if the
system fails to respond after six
minutes of bootup attempt.

Disable FRB2 Timer

Disable BSP

Do not disable BSP

Retry 3 times

Thermal Sensor

Specifies whether BIOS will disable
boot when system temperature is
outside the safe range.

Disabled

Enabled

BMC IRQ

Specifies the routing address for
the BMC interrupt.

Disabled

5

10

11

Post Error
Pause

When enabled, if the POST finds an
error, it will pause and the user has
to press F1 to continue.

If disabled, even when the POST
finds an error, it will not pause.
This may result to reduced system
functionality.

Disabled

Enabled

AC-Link

Sets the AC-Link mode.

Last State

Power on

Stay off

Platform Event
Filtering

Specifies whether to enable or
disable the trigger elements for
system sensor events.

Disabled

Enabled

Parameter

Description

Option

BB!H:11!vh!.!FO/cppl!!Qbhf!248!!Gsjebz-!Kbovbsz!28-!3114!!8;24!QN