225

0B92:

Internal Use Area of BMC
FRU corrupted.

SROM storing chassis
information failed

Available for use except for
FRU command and
emergency management
port function.

0B93:

BMC SDR Repository empty.

BMC device (chip) failed

0B94:

IPMB signal lines do not
respond.

SMC (Satellite Management
Controller) failed

Available for use except for
the access function to SMC
via IPMB.

0B95

BMC FRU device failure.

SROM storing chassis
information failed

Available for use except for
FRU command and
emergency management
port function.

0B96

BMC SDR Repository failure.

BMC device (chip) failed

0B97

BMC SEL device failure.

BMC device (chip) failed

0BB0:

SMBIOS - SROM data read
error

SROM data read error

0BB1:

SMBIOS - SROM data
checksum bad

Bad checksum of SROM data

0BD0:

1st SMBus device address not
acknowledged.

Some SMBus device (chip)
failed

0BD1:

1st SMBus device Error
detected.

Some SMBus device (chip)
failed

0BD2:

1st SMBus timeout.

Some SMBus device (chip)
failed

Expansion ROM not
initialized.

PCI Expansion ROM card not
initialized

Code

Error Message

Failure Description

BB!H:11!vh!.!FO/cppl!!Qbhf!336!!Gsjebz-!Kbovbsz!28-!3114!!8;24!QN