Removing and installing a power supply module – Acer Altos G901 User Manual

Page 98

Advertising
background image

3 Hardware configuration

82

Refer to the table below for a list of LED states and the power supply
status indicated by each state.

Note: If all power supply modules are functioning and all power
cables from the power distribution board are properly connected
to the

mainboard

and other components, but the server won't

power on, replace the power distribution board (refer to
page 101).

Removing and installing a power supply module

To remove a power supply module

1

Disconnect the AC power cord for the supply from the wall outlet
or power source.

2

Remove the four screws that secure the power supply.

3

Pull the latch handle to release the power supply module and
carefully pull the module out of the power supply bay.

Power
(Green)

Predictive
fail
(Amber)

Fail
(Amber)

Status

Off

Off

Off

No power to all power supplies.

Off

Off

On

Power supply failure or no
power to this power supply.

Blinking

Off

Off

AC power present, standby
outputs on.

On

Off

Off

Power supply on, DC outputs
normal.

On

Off

Blinking

Current limit.

On On

or

Blinking

Off

Imminent failure predicted; fan
performance problem.