Task 8: connect the maintenance modem, Task 9: finalize and test the hardware – AT&T DEFINITY 555-230-223 User Manual

Page 46

Advertising
background image

Installation

j. Enter

ATDT

and the phone number of the 7400A data set

connected to the DEFINITY LAN Gateway system (refer to
Worksheet B-1, ‘‘Terminals/Modems’’ for this number).

After a connect interval, if the terminal and 7400 data sets are
installed correctly (and the system is in either OAM or OS state),
the screen displays the login prompt.

If the login prompt is not displayed when the system is in one of the
above states, try pressing the

Return

key a few times. If the login

prompt still does not appear, write down the state displayed on the
LCD and then see the troubleshooting procedure for terminal
connections in Appendix D.

Task 8: Connect the Maintenance Modem

For this task, make sure you have the correct ED-1E434 Group 311 cable (in a
length between 5 and 50 feet).

1. Physically connect the cable to the modem.

2. Set the modem options.

3. After you have connected the modem and established dial tone, record

the telephone number. You will call the TSC and give them the telephone
number of the modem in a later procedure.

Task 9: Finalize and Test the Hardware

This task is required for all installation scenarios.

1. Verify that the DEFINITY LAN Gateway system hardware and software

components are installed properly. At the DEFINITY G3-MT, enter

list

configuration board <loc>

. The screen that appears should display

LGATE Board

in the

Board Type

field. (See Screen 2-2 later in this

chapter for an example.)

2. Verify that the system is in the ASAI state.

Stand to the right of the system assembly and read from bottom to top.
The LCD should display ASAI X, where X is the number of connections.

3. Log in to the DEFINITY LAN Gateway system at the terminal to verify that

the terminal and modems (if applicable) are connected and set up
correctly.

Issue 1 January 1996

2-27

Advertising