22

Commissioning

4.5.3

Advanced Setup Parameters

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

Speed at
Minimum Signal

0.0

-999.0

{Hz}

000

f

P161

P160

ref

10V

(20mA)

0V

(4mA)

V0

Speed at
Maximum Signal

0.0

-999.0

{Hz}

000

Note
• P0 sets the output frequency at 0% analog input
• P sets the output frequency at 00% analog input
• P0 or P < 0.0 Hz: For scaling purposes only; does not indicate

opposite direction!

• P0 > P: Drive will react inversely to analog input signal

Analog Input
Filter

0.0

0.00

{s}

0.00

Adjusts the filter on the analog inputs
(TB-5 and TB-25) to reduce the effect
of signal noise

TB-25 Loss
Action

0

0 No Action

• Selects the reaction to a loss of the

4-20 mA signal at TB-25.

• Signal is considered lost if it falls

below 2 mA

• Digital outputs can also indicate a

loss of 4-20 mA signal; see P40,
P42

 Fault
2 Go to Preset when TB-25 is:
Speed reference: P7
PID feedback source: P7
PID setpoint reference: P2
Torque reference: P

Carrier
Frequency



0 4 kHz

• As carrier frequency is increased,

motor noise is decreased

• Observe derating in Section 2.2
• Automatic shift to 4 kHz at 20%

load

  kHz
2 8 kHz
 0 kHz

()

Base Frequency

0.0

0.0

{Hz}

500

V02

Fixed Boost

0.0

{%}

0.0

Note
• P7 = rated motor frequency for standard applications
• P8 default setting depends on drive rating

Accel Boost

0.0

0.0

{%}

20.0

Accel Boost is only active during
acceleration

() Any changes to this parameter will not take effect until the drive is stopped