Troubleshooting and diagnostics, English 4 – AC International Lenze SV01B User Manual

Page 35

Advertising
background image

ENGLISH

4

Troubleshooting and Diagnostics

Fault

Cause

Remedy

(1)

Digital Input
Configuration fault
(P2...P2)

More than one digital input set for
the same function

Each setting can only be used once
(except settings 0 and )

Only one digital input configured for
MOP function (Up, Down)

One input must be set to MOP Up,
another must be set to MOP Down

PID mode is entered with setpoint
reference and feedback source set
to the same analog signal

Change PID setpoint reference
(P2…P2) or feedback source
(P20).

One of the digital inputs (P2…
P2) is set to 0 and another is
set to …4.

Reconfigure digital inputs

One of the digital inputs (P2…
P2) is set to  or 2 and another
is set to  or 4.
PID enabled in Vector Torque mode
(P200 =  or 2 and P00 = 5)

PID cannot be used in Vector
Torque mode

Remote keypad fault

Remote keypad disconnected

Check remote keypad connections

Low DC Bus Voltage fault Mains voltage too low

Check mains voltage

No Motor ID fault

An attempt was made to start the
drive in Vector or Enhanced V/Hz
mode prior to performing the Motor
Auto-calibration

See P00…P99 for Drive Mode
setup and calibration.

Module communication
fault

Communication failure between
drive and Network Module.

Check module connections

Network Faults

Refer to the module documentation.
for Causes and Remedies.

Output fault:
Transistor fault

Output short circuit

Check motor/motor cable

Acceleration time too short

Increase P04, P25

Severe motor overload, due to:
• Mechanical problem
• Drive/motor too small for

application

• Check machine / system
• Verify drive/motor are proper size

for application

Boost values too high

Decrease P8, P9

Excessive capacitive charging
current of the motor cable

• Use shorter motor cables with

lower charging current

• Use low capacitance motor

cables

• Install reactor between motor and

drive.

Failed output transistor

Contact factory technical support

Output fault: Ground fault Grounded motor phase

Check motor and motor cable

Excessive capacitive charging
current of the motor cable

Use shorter motor cables with lower
charging current