Troubleshooting and Diagnostics

Fault

Cause

Remedy

(1)

Motor Overload fault

Excessive motor load for too long

• Verify proper setting of P08
• Verify drive and motor are proper

size for application

Flying Restart fault

Controller was unable to
synchronize with the motor during
restart attempt; (P0 = 5 or )

Check motor / load

Single-Phase fault

A mains phase has been lost

Check mains voltage

Start fault

Start command was present when
power was applied (P0 = 0 or 2).

• Must wait at least 2 seconds

after power-up to apply Start
command

• Consider alternate starting

method (see P0).

() The drive can only be restarted if the error message has been reset