Commissioning

4.5.6

Network Parameters

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

Network Protocol

0 Not Active

This parameter will only display
the selection for the module that is
installed.

 Remote Keypad
2 Modbus RTU
 CANopen
4 DeviceNet
5 Ethernet
 Profibus

Module Specific Parameters

Refer to the Reference Guide specific
to the module installed.

4.5.7

Diagnostic Parameters

Code

Display Range

(READ ONLY)

IMPORTANT

No.

Name
Fault History

• Displays the last 8 faults
• Format: n.xxx

where: n = ..8;

 is the newest fault

xxx = fault message (without the

.)

• see Section 5.

Software version

Format: x.yz

Drive ID

A flashing display indicates that the Drive ID
stored in the EPM does not match the drive
model it is plugged into.

Internal Code

Alternating Display: xxx-; -yy

DC Bus Voltage

0

{VDC}

500

Motor Voltage

0

{VAC}

000

Load

0

{%}

255

Motor load as % of drive’s output current rating.
See section 2.2.

Motor Current

0.0

{A}

000 Actual motor current

Torque

0

{%}

500

Torque as % of motor rated torque
(vector mode only)

kW

0.00

{kW}

50.0

kWh

0.0

{kWh}

9999999 Alternating display: xxx-; yyyy when value

exceeds 9999

Heatsink Temp

0

{°C}

50

Heatsink temperature

0-0 VDC Input

0.0

{VDC}

0.0

Actual value of signal at TB-5

4-20 mA Input

0.0

{mA}

20.0

Actual value of signal at TB-25

TB-5 Feedback

P204

P205 TB-5 signal value scaled to PID feedback units

TB-25 Feedback P204

P205 TB-25 signal value scaled to PID feedback units