Troubleshooting and Diagnostics

5.3

Fault Messages

The messages below show how they will appear on the display when the drive trips. When looking at
the Fault History (P500), the

. will not appear in the fault message.

Fault

Cause

Remedy

(1)

High Temperature fault

Drive is too hot inside

• Reduce drive load
• Improve cooling

Assertion Level fault

• Assertion Level switch is

changed during operation

• P20 is changed during

operation

P00 or P2...P2 are set to
a value other than 0 and P20
does not match the Assertion
Level Switch.

• Make sure the Assertion Level

switch and P20 are both set for
the type of input devices being
used, prior to setting P00 or
P2...P2.
See .2. and P20.

Personality fault

Drive Hardware

• Cycle Power
• Power down and install EPM with

valid data

• Reset the drive back to defaults

(P99 = , 4) and then re-
program

• If problem persists, contact

factory technical support

Control fault

An EPM has been installed that is
either blank or corrupted

Incompatible EPM fault

An EPM has been installed that
contains data from an incompatible
parameter version

Dynamic Braking fault

Dynamic braking resistors are
overheating

• Increase active decel time

(P05, P2, P27).

• Check mains voltage and P07

External fault

• P2…P2 = 2 and that digital

input has been opened.

• P2…P2 = 22 and that digital

input has been closed.

• Correct the external fault

condition

• Make sure digital input is set

properly for NC or NO circuit

EPM fault

EPM missing or defective

Power down and replace EPM

Internal faults

Contact factory technical support

Invalid message received • A network message was

received while in Remote Keypad
mode

• A remote keypad message was

received while in Network mode

Only the remote keypad or the
network can be connected at one
time; see P00

Loss of 4-20 mA signal
fault

4-20 mA signal (at TB-25) is below
2 mA (P = )

Check signal/signal wire

OEM Defaults data fault

Drive is powered up with
P99 = and OEM settings in the
EPM are not valid.

Install an EPM containing valid
OEM Defaults data or change P99
to 0.

High DC Bus Voltage
fault

Mains voltage is too high

Check mains voltage and P07

Decel time is too short, or too much
regen from motor

Increase active decel time
(P05, P2, P27) or install
Dynamic Braking option

() The drive can only be restarted if the error message has been reset