Table 6

Troubleshooting Pump

PROBLEM /

MALFUNCTION

PROBABLE CAUSE

REMEDY

Motor requires
excessive power

Head lower than rating. Pumps too much
liquid

Install throttle valve.

Liquid heavier than expected.

Check specific gravity and viscosity.

Head higher than rating, capacity at
rating

Check impeller diameter.

Rotating parts binding or severly worn

Check internal wearing parts for proper
clearances.

Condition
monitoring device
shuts down pump

Damaged sleeve & thrust bearings

Replace as required.

Plugged recirculation circuit

Disassemble and remove blockage. Determine and
correct cause of blockage.

Recirculation liquid vaporization

Check actual liquid temperature versus design
temperature. Check actual NPSH available versus
design. Check minimum flow requirement for pump
size. Check recirculation circuit and flush screen for
blockage. Correct all as necessary.

Damaged containment shell

Replace as required.

Magnets decoupled

Check temperature and viscosity of pumpage. Check
magnets with breakaway torque test.

Pump run dry

Check control device for proper operation. Check

suction line for blockage. Reprime pump.

Excessive motor power

System head lower than rating. Pumps too much liquid.
Check rotating parts for binding and wear. Liquid
heavier than expected.