Condition monitoring devices, Goulds total protection system (option), Description – Goulds Pumps 3296M - IOM User Manual

Page 84: Components

Advertising
background image

CONDITION MONITORING DEVICES

Goulds Total Protection System (Option)

DESCRIPTION

The Goulds Total Protection System (GTP System) is a controller designed to protect the 3296 from damage that
may occur due to abnormal operating conditions. Five input channels provide sensing capability for AC motor
`current, containment shell temperature, vibration level, containment shell leakage and a system pressure switch.
The controller will sound an alarm and/or shut down the pump if any of the system set points are exceeded.

COMPONENTS

Supplied with Unit

(1) GTP System Controller with
(1) AC Current Sense Transformer and instructions

Part No.

A03792A

Available - Must be Ordered Separately

(1) Leak Detection Pressure Switch

- NEMA 4

Part No.

A03787A

- NEMA 7

Part No.

A03788A

(1) Vibration Transmitter

- NEMA 4

Part No.

A05075A

- NEMA 7

Not Available

NOTE: To attain a NEMA 7 rating on the vibration transmitter, a safety barrier is required to limit power to
the unit. This specialized equipment is beyond the scope of Goulds' supply and responsibility. Contact Balmac,
Inc. 614-876-1295 for further information.

Not Supplied

System Pressure Switch - This must be supplied by the customer due to the diversity of requirements such as
pressure range and materials of construction.

80

3296 M Group 6/05

Advertising