Warning – Goulds Pumps 3296M - IOM User Manual

Page 35

Advertising
background image

9.

Remove clamp ring screws (370B) and lock
washers (136A) (Fig. F).

s

!

WARNING

Use non-magnetic socket and speed wrench to
avoid personal injury or damage to parts.

10. Remove clamp ring (141C) and containment shell

(750) simultaneously (Fig. F).

11. Remove O-ring (412M) and discard (Fig. F).

12. Orient frame adapter assembly in vertical position

and support on blocks (Fig. G).

NOTE: Place a folded clean cloth or cardboard

under frame adapter assembly to soften impact of
driven magnet assembly (740A) on work surface.
Shaft and magnet assembly should rest on work
surface.

13. Remove impeller (101) (Fig. H).

NOTE: It may be necessary to use a puller. Puller
must be placed under vanes so as not to damage
the impeller.

14. Press driven shaft (122A) out until it disengages

(Fig. I).

NOTE: Light tapping with a non-metallic
hammer may be necessary to disengage shaft.

3296 M Group 6/05

31

Advertising