Goulds Pumps 3296M - IOM User Manual

Page 34

Advertising
background image

5.

Place unit in vertical position resting on
non-magnetic blocks (Fig. C).

s

!

WARNING

Pump and some individual components weigh
more than 50 lbs (23 kg). Care should be taken
when handling.

6.

Remove frame adapter bolts (370) (Fig. C).

7.

Remove bearing frame using four (4) jacking
screws (Fig. D).

s

!

WARNING

Do NOT attempt to remove bearing frame (228)
without using the jacking screws. Personal injury
and damage to the magnets will occur.

8.

Evenly tighten bearing frame jacking screws until
bearing frame (228) is above containment shell
(750) as shown. Lift bearing frame (228) off
frame adapter (108) and set aside away from
attracting metals.

Use of a lifting device with a strap through two
opposite eyes in the jacking screws is
recommended.

Remove adapter to frame gasket (360W) and
discard (Fig. E).

s

!

WARNING

The magnets contained in this unit are extremely
powerful. Keep magnetic drive components and
magnetic tools apart from each other by a
minimum of six (6) feet [two (2) meters]. Serious
injury to fingers and hands will result.

s

!

WARNING

This component can weigh more than
50 lbs (23 kg). Care should be taken when
handling.

30

3296 M Group 6/05

Advertising