Condition monitoring devices, Nema 4 pressure switch (option) leak detector – Goulds Pumps 3296M - IOM User Manual

Page 77

Advertising
background image

CONDITION MONITORING DEVICES

NEMA 4 Pressure Switch (Option)

Leak Detector

DESCRIPTION

This detector senses a leak in the containment shell by detecting pressure in the bearing frame bell housing. A
pressure switch preset to trip at 10 PSIG on increasing pressure is supplied. The switch must be wired to the
customer's monitoring system to sound an alarm and/or stop the pump. Recommended for use with volatile liquids
(liquids that will flash when exposed to atmospheric pressure). Should be provided to those customers who require
warning of containment shell leakage.

LIMITATIONS

1.

The total developed pressure of the pump plus suction pressure must be above 15 PSIG in order to have
sufficient pressure in containment shell to trip switch should there be a leak.

l

!

CAUTION

This method of leak detection may not prevent release of pumpage to the atmosphere. It is possible that liquid
could infiltrate bearing frame lubricating oil.

COMPONENTS SUPPLIED

(1) Pressure Switch - Custom Control Sensors, Inc., Model 6703 G 8001

Specifications

Rating - NEMA4
¼ - 18 NPT Pressure Port
½ - 14 NPT Conduit Connection
18" Free Leads
Wetted Parts

* Aluminum
* Polyimide
* Buna N
* Cadmium Plated Steel
* 300SS

Trip Point - Preset at 10 PSIG (69 kPa) on increasing pressure

Switch Element

* SPDT
* 120/240 VAC
* 50/60 Hz
* 11 Amps

Ambient Temperature Range

-30° F to 160° F (-34° C - 71° C)

3296 M Group 6/05

73

Advertising