Caution – Goulds Pumps 3296M - IOM User Manual

Page 67

Advertising
background image

14. Ensure impeller key (178) is in shaft keyway and

align impeller keyway to it.

15. While keeping light tension on the threaded rod,

prevent rod from turning while tightening the
jacking nut. Tighten nut until impeller is seated.

l

!

CAUTION

Ensure impeller starts squarely on the shaft. If
impeller cocks, loosen nut slightly and tap
LIGHTLY on the outside diameter of the impeller
until it is square. Ensure shaft does not slide
rearward.

16. Remove threaded rod and install impeller screw

(198), lockwasher (199A) and impeller washer
(199).

17. Torque impeller bolt, set lockwasher, install back

pull-out, align pump, etc. As specified in Section
6, Reassembly, steps 56 through 64.

3296 M Group 6/05

63

Advertising