CONDITION MONITORING DEVICES

Temperature Controller (Option)

DESCRIPTION

The temperature controller monitors the temperature signal from the temperature sensor (usually the thermocouple)
to alarm and/or stop the pump if an over-temperature condition exists. If the customer does not have a controller to
work with the thermocouple, this option should be provided. Common set points are the maximum temperature of
the magnetic coupling, the boiling point of the pumpage or solidification temperature of the pumpage. The
controller will also trip if the temperature sensor is disconnected or the electrical power supply is interrupted.

COMPONENTS SUPPLIED

(1) Controller with instructions
(1) Terminal Socket

Specifications

Make – Omega
Model – 6102
Type – J
Range – 0° F to 500° F
Supply Voltage – 120 VAC 50/60 Hz
Power Consumption – 2 VA
Output Relay – 7A

MOUNTING LOCATION

It is recommended to mount components in an enclosure to avoid excessive shock, vibration, dirt, moisture and oil.
an area with ambient temperature between 32° F and 122° F (0° C and 50° C), such as the motor starter enclosure or
in a control room.

INSTRUCTION

Wire to thermocouple, motor starter control circuit (and/or alarm) and to 120 VAC source as shown in wiring
diagram. Set trip point to desired alarm/shutdown temperature.