45. Remove bearing wavewasher (529) from bearing

bore (Fig. Y).

46. Remove drive shaft (122B) with ball bearings

(112) from bearing housing (228) (Fig. Y).

47. Press bearings (112) off shaft and discard.

48. Remove lip seal (333D) as shown and discard

(Fig. Z).

INSPECTIONS

Model 3296 parts must be inspected to the following
criteria before reassembly to ensure pump will run
properly. Any part not meeting required criteria should
be replaced.

NOTE: Various tolerances specified on the 3296
are held extremely close, measure parts at standard
temperature 68°F(20°C) to ensure accurate
measurement.

CASING (100)

Casing (100) should be inspected for excessive wear or
pitting. It should be repaired or replaced if it exceeds
the following criteria.

Table 8

Minimum Casing

Thickness

Group

Pump Size

Minimum

Thickness Inches

(mm)

M

2x3-8
3x4-8
3x4-8G
1x2-10
2x3-10
3x4-10H
1

1

2

x3-13

2x3-13

0.31 (7.9)
0.31 (7.9)
0.31 (7.9)
0.37 (9.4)
0.37 (9.4)
0.37 (9.4)
0.37 (9.4)
0.37 (9.4)