8 packing and mechanical seal maintenance, 1 packing seal replacement, Figure 8-1: pump packing seal overview – Hale Q Series Muscle User Manual

Page 131: 8packing and mechanical seal maintenance

Advertising
background image

131

MUSCLE (Midship) Pumps Installation, Operation, and Maintenance Manual
p/n: 029-0020-63-0

Packing and Mechanical Seal Maintenance

8

Packing and Mechanical Seal Maintenance

8.1 PACKING SEAL REPLACEMENT

When the packing adjustment has reached its limit, a single ring of packing can be
added. However, it is usually more efficient to repack the pump. (See Figure 8-1:
“Pump Packing Seal Overview.”) Also
see Figure 8-2: “Packing / Mechanical Seal
Assembly Overview” on page 132.

Figure 8-1: Pump Packing Seal Overview

Review preceding sections “Before You Begin...,” on page 103 and “Cleaning and
Inspection Guidelines,” on page 106.

The three rings adjacent to the packing gland can be replaced without disassembling
the pump. The ring in front of the lantern does not need to be replaced. (See Figure 8-
1: “Pump Packing Seal Overview.”)

WARNING!

DO NOT RUN THE ENGINE WHILE PERFORMING ANY SERVICING TO THE PACKING,
I.E., PACKING SEAL ADJUSTMENT OR REPLACEMENT.